Packet Tracer Remote IoT Smart Office
Sydney Smart Office Design:
The basic file consist of few smart devices like ceiling fan, lamp, tablet PC rest of all smart devices s will be added manually. Those devices are mentioned as under.
• Front Door
• Windows (3 Numbers )
• Motion Detector
• Ceiling Fan
• Smoke Detector
• Lawn Sprinkler System
• Wind Speed Detector
• Temperature Monitor
As shown in above screenshot server, windows1,2, 3,temperature monitor, wind speed detector, motion detector, lawn sprinkler, smog detector is added manually.
1.
SS1.1
SS1.2 IOT service has been enabled on registration server as shown in above diagram.
SS1.3
Remote server received IP from DHCP request that is 209.165.220.2, now registration server is configured and enabled.
2.
SS2.1
Now wireless router has been encrypted and SSID is changed to "Sydney office" and pass phrase is set to ‘11666308' that is of student ID.
SS2.2
As shown in screenshot Tablet is set to connect with wireless router.
SS2.3
After that Registration server account is configured and login ID and password are set to student ID as shown above.
3
SS3.1
After Registration server account window 3 is configured to connect router by wireless connection.
SS3.2
Now window 3 is configured to connect with router and registered on remote server for that server address is 209.165.220.2 and Username and password is set to Student ID that is ‘11666308'.
Same as above procedure all smart devices are connected and registered on Remote server
SS3.3
Here all of the IOT devices are connected to router and registered in IOT registration server as shown in the above screenshot.
SS3.4
This is the scenario before operating smart devices from tablet.
SS3.5
And in the above state devices are being controlled by tablet.
4
SS4.1
Above screenshot shows the list of protocols which are used during the transmission of a simple PDU data from the tablet to the remote server in progress, in PDU of source IP is 209.165.220.1 and destination IP is 209.165.220.2 these are the IP address of Tablet and Remote server respectively.
SS4.2
In the above screenshot it shows the list of protocols that are used in transmission a simple PDU data received at remote server, in PDU of source IP is 209.165.220.2 which is actually an IP address of tablet and destination IP is 209.165.220.1 which is the IP of registration server.
Section-2: In this section we have to control all of the smart devices from the branch office located in the same city.
5.
SS5.1
Now, as per the requirement, to control all of the smart devices from Bathurst new city in physical mode, new branch office is added in packet tracer.
SS5.2
SS5.3
After that we have added tablet and wireless router to wiring closet in Bathurst city. And that is shown above in logical mode.
SS5.4
Now tablet at Bathurst has access to control the remote devices as shown in screenshot.
6
• Turn off the Sprinkler
• Lock the door
• Turn off the ceiling fan
SS5.5
Screenshot before controlling devices from tablet
SS5.6
Controlling devices from tablet
SS5.7
• Close Window2 and Window1 when the level of carbon monoxide or carbon dioxide higher in outside environment.
SS5.8
Screenshot shows topology before sensor value is low. Old car carbon dioxide, carbon monoxide are added manually to sense carbon dioxide level.
SS5.9
Screenshot shows that the condition set if carbon dioxide and carbon monoxide value is go high then the window1 and 2 get closed.
SS5.10
Screenshot shows that after starting car windows are closed.